Dear bacula users,

using bacula 9.0.4.

My situation: I have two nearly identical LTO-6 libraries. I use "Neo400" for 
Full backups "FlexStorII" for Diff backups. bacula-sd.conf is attached.

Preparing a restore that needs a full and a diff backup I get the output:

The Job will require the following (*=>InChanger):
   Volume(s)                 Storage(s)                SD Device(s)
===========================================================================

   *LTO6-020                  Neo400                    Neo400
   *LTO6-002                  FlexStorII                FlexStor2

Volumes marked with "*" are in the Autochanger.


So LTO6-020 (Full) is in Neo400 while LTO6-002 is in FlexStorII. Both are 
available. 
Starting the restore leads to:

17-Jul 12:40 bacula-dir JobId 1016825: Start Restore Job 
RestoreFiles.2018-07-17_12.40.22_19
17-Jul 12:40 bacula-dir JobId 1016825: Using Device "LTO6-1" to read.
17-Jul 12:40 bacula-sd JobId 1016825: 3307 Issuing autochanger "unload Volume 
LTO6-002, Slot 3, Drive 1" command.
17-Jul 12:40 bacula-sd JobId 1016825: 3304 Issuing autochanger "load Volume 
LTO6-020, Slot 20, Drive 1" command.
17-Jul 12:41 bacula-sd JobId 1016825: 3305 Autochanger "load Volume LTO6-020, 
Slot 20, Drive 1", status is OK.
17-Jul 12:41 bacula-sd JobId 1016825: Ready to read from volume "LTO6-020" on 
Tape device "LTO6-1" (/dev/tape/by-id/scsi-35000e11150246004-nst).
17-Jul 12:41 bacula-sd JobId 1016825: Forward spacing Volume "LTO6-020" to 
addr=88:0
17-Jul 12:42 imap3 JobId 1016825: drwxr-xr-x  15 root     root            4096 
2016-01-18 10:42:03  /tmp/bacula-restores/var/spool/
17-Jul 12:44 imap3 JobId 1016825: drwxr-xr-x   4 cyrus    mail              34 
2016-01-19 04:58:27  /tmp/bacula-restores/var/spool/imap/l/
17-Jul 12:45 imap3 JobId 1016825: -rw-------   1 cyrus    mail             128 
2017-03-31 12:35:19  
/tmp/bacula-restores/var/spool/imap/l/user/litauer/Trash/cyrus.index
17-Jul 12:45 imap3 JobId 1016825: -rw-------   1 cyrus    mail               4 
2017-03-31 12:35:19  
/tmp/bacula-restores/var/spool/imap/l/user/litauer/Trash/cyrus.cache
17-Jul 12:45 imap3 JobId 1016825: -rw-------   1 cyrus    mail             189 
2017-03-31 12:35:19  
/tmp/bacula-restores/var/spool/imap/l/user/litauer/Trash/cyrus.header
17-Jul 12:45 imap3 JobId 1016825: drwx------   2 cyrus    mail              77 
2017-03-31 12:35:19  /tmp/bacula-restores/var/spool/imap/l/user/litauer/Trash/
17-Jul 12:47 bacula-sd JobId 1016825: End of Volume "LTO6-020" at addr=136:8676 
on device "LTO6-1" (/dev/tape/by-id/scsi-35000e11150246004-nst).
17-Jul 12:47 imap3 JobId 1016825: drwxr-xr-x  17 root     root            4096 
2017-07-06 13:50:37  /tmp/bacula-restores/var/
17-Jul 12:47 bacula-sd JobId 1016825: 3307 Issuing autochanger "unload Volume 
LTO6-020, Slot 20, Drive 1" command.
17-Jul 12:48 bacula-sd JobId 1016825: 3304 Issuing autochanger "load Volume 
LTO6-002, Slot 3, Drive 1" command.
17-Jul 12:49 bacula-sd JobId 1016825: 3305 Autochanger "load Volume LTO6-002, 
Slot 3, Drive 1", status is OK.
17-Jul 12:49 bacula-sd JobId 1016825: 3307 Issuing autochanger "unload Volume 
LTO6-002, Slot 3, Drive 1" command.
17-Jul 12:50 bacula-sd JobId 1016825: Warning: acquire.c:279 Read acquire: 
Wrong Volume mounted on Tape device "LTO6-1" 
(/dev/tape/by-id/scsi-35000e11150246004-nst): Wanted LTO6-002 have LTO6-003
17-Jul 12:50 bacula-sd JobId 1016825: 3304 Issuing autochanger "load Volume 
LTO6-002, Slot 3, Drive 1" command.
17-Jul 12:50 bacula-sd JobId 1016825: 3305 Autochanger "load Volume LTO6-002, 
Slot 3, Drive 1", status is OK.
17-Jul 12:50 bacula-sd JobId 1016825: 3307 Issuing autochanger "unload Volume 
LTO6-002, Slot 3, Drive 1" command.
17-Jul 12:51 bacula-sd JobId 1016825: Warning: acquire.c:279 Read acquire: 
Wrong Volume mounted on Tape device "LTO6-1" 
(/dev/tape/by-id/scsi-35000e11150246004-nst): Wanted LTO6-002 have LTO6-003

As you can see, tape LTO6-002 is found in slot 3. So bacula tries to load slot 
3 -- but uses library Neo400 instead of FlexStorII. This results in a "wrong 
volume" error.
Is this a bug or should I configure my libraries in some other way? Maybe the 
problem is that both libraries are of type LTO6?

-- 
Kind regards
Christoph Litauer
_________________________________________
Uni Koblenz, Rechenzentrum, Raum A 022    
Postfach 201602, 56016 Koblenz     
Fon: +49 261 287-1311, Fax: -100 1311



Attachment: bacula-sd.conf
Description: Binary data

------------------------------------------------------------------------------