I found the cause for the following daemon message:

Subject: Bacula daemon message
15-Sep 01:29 lx-vihost-1-dir JobId 0: Error: bsock.c:544 Bsock send
while terminated=1 on call to client:127.0.0.1:9101

It is caused by using the following line in bash backup start and end scripts:

   echo release | bconsole

The command allways askes for a slot number - unneccessarily. The bsock
error then is repeated 4 times.

We use the command for many years now, to move all cassettes back to
start position e.g. for easier manual access. The error message is only
since the change to the Bacula 9.0.x versions.

--
Ralf Brinkmann


------------------------------------------------------------------------------