On 11/1/2016 7:44 AM, Wanderlei Huttel wrote:
I'm using bacula 7.4.4 with vchanger and when I check the logs I see this message, but it command worked.

Connecting to Storage daemon VirtualChanger at 192.168.1.3:9103 <http://192.168.1.3:9103> ...
Sending label command for Volume "Volume-Diario-0009" Slot 9 ...
3304 Issuing autochanger "load slot 9, drive 0" command for vol Volume-Diario-0009. Volume label failed: Storage Daemon and Director are incompatible versions.3305 Autochanger "load slot 9, drive 0", status is OK for vol Volume-Diario-0009. Volume label failed: Storage Daemon and Director are incompatible versions.3000 OK label. VolBytes=207 VolABytes=0 VolType=1 Volume="Volume-Diario-0009" Device="Drive0" (/var/spool/vchanger/0) Catalog record for Volume "Volume-Diario-0009", Slot 9 successfully created.


Both versions of bacula-dir and bacula-sd are in 7.4.4

Are you sure? I believe that message means that they are not. Perhaps one of the daemons was not restarted when updating. Try stopping both daemons and making sure there are no zombie processes running, then start and check versions.


------------------------------------------------------------------------------