Hello, 2015-12-17 19:33 GMT+01:00 Gilberto Nunes <gilberto.nune...@gmail.com>:
> 17-Dec 16:30 storage-global-sd: ERROR in bget_msg.c:95 bget_msg: unknown > signal -1827994119 > 17-Dec 16:30 storage-global-sd JobId 1003: Fatal error: bsock.c:570 Packet > size=2102457799 too big from "client:172.16.254.5:9103. Terminating > connection. > Something/someone is mangling your network transmission. Every message exchanged in Bacula consist of a following stream: <packet size><data of "packed size" bytes><packet size><data of "packed size" bytes>...<signal> So during your backup Bacula SD received a <packet size> which value was: 2102457799, but Bacula allow packet size to be no greater then 10^6 bytes. The signal is a value less then zero. You need to verify what is going on on your network or servers. best regards -- Radosław Korzeniewski rados...@korzeniewski.net
------------------------------------------------------------------------------
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users