Hello,
2015-12-05 21:09 GMT+01:00 dbgtmaster <bacula-fo...@backupcentral.com>:
> Hi,
>
> i am using bacula 7.0.
>
> Some of my backup clients are in aother country as the storage daemon.
>
> Sometimes, the backup cancel with the folliwing error:
>
> Time: 2015-12-05 01:46:51
> LogText: srvletternode-rus1-1-fd JobId 11687: Error: bsock.c:427 Write
> error sending 65540 bytes to Storage
> daemon:srvbackup-rz1-1.eyepin.local:9103: ERR=Connection timed out
> Time: 2015-12-05 01:46:51
> LogText: srvletternode-rus1-1-fd JobId 11687: Fatal error: backup.c:1200
> Network send error to SD. ERR=Connection timed out
> Time: 2015-12-05 01:47:01
> LogText: srvbackup-rz1-1-dir JobId 11687: Error: Director's connection to
> SD for this Job was lost.
>
> Is there a way to configure bacule to reconnect the the sd, if the
> connection go away?
>
>
No, when Bacula makes a connection (after succesful connect()) then any
disconnection will terminate a job with error status. It is not possible to
reconnect with current code.
best regards
--
Radosław Korzeniewski
rados...@korzeniewski.net
------------------------------------------------------------------------------
Go from Idea to Many App Stores Faster with Intel(R) XDK
Give your users amazing mobile app experiences with Intel(R) XDK.
Use one codebase in this all-in-one HTML5 development environment.
Design, debug & build mobile apps & 2D/3D high-impact games for multiple OSs.
http://pubads.g.doubleclick.net/gampad/clk?id=254741911&iu=/4140
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users