Hello Distribution: Ubuntu 12.04
Issue: Bacula does not properly recognize the 12 tape slots of the ADIC-1200 G. Details: 1) *update slots scan 3306 Issuing autochanger "slots" command. Device "AutoChanger1" has 0 slots. No slots in changer to scan. 2) If I start bacula-sd directly, it works # service bacula-sd stop * Stopping Bacula Storage daemon... [ OK ] # /usr/sbin/bacula-sd # bconsole Connecting to Director 127.0.0.1:9101 *update slots scan ... Connecting to Storage daemon TapeStorage2 ... 3306 Issuing autochanger "slots" command. Device "AutoChanger1" has 12 slots. 3) I would think of a permission problem. The file permissions seem however not be related to this issue. # ls -la /dev/sg0 crw-rw---- 1 root tape 21, 0 Mar 5 19:14 /dev/sg0 # ls -la /etc/bacula/scripts/mtx-changer -rwxr-xr-x 1 bacula bacula 7524 Mar 2 11:14 /etc/bacula/scripts/mtx-changer # chmod 0666 /dev/sg0 # service bacula-sd start * Starting Bacula Storage daemon... [ OK ] # beconsole *update slot scan 3306 Issuing autochanger "slots" command. Device "AutoChanger1" has 0 slots. No slots in changer to scan. I would appreciate help.... Thanks Tilman ------------------------------------------------------------------------------ Everyone hates slow websites. So do we. Make your web apps faster with AppDynamics Download AppDynamics Lite for free today: http://p.sf.net/sfu/appdyn_d2d_feb _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users