Yes, LTP102L1 is a tape volume.
I defined Maximum Volumes = 1000 ; as you said, it would be better having no line like this ; but I think it would be the same :

having sometimes :
Error: block.c:590 Write error at 88:2499 on device "OVL_LTO-3_Drive-2" (/dev/st0). ERR=Erreur d'entrée/sortie.
Error: Error writing final EOF to tape. This Volume may not be readable.
dev.c:1566 ioctl MTWEOF error on "OVL_LTO-3_Drive-2" (/dev/st0). ERR=Erreur d'entrée/sortie.

rarely, it marks the volume full when it is reallyy full like here :
End of Volume "000352L3" at 406:13452 on device "OVL_LTO-3_Drive-1" (/dev/st1). Write of 64512 bytes got -1.
Re-read of last block succeeded.
End of medium on Volume "000352L3" Bytes=406,841,831,424 Blocks=6,306,451 at 20-nov.-2012 09:27.

Thanks
Jacky

Le 20/11/2012 09:15, Radosław Korzeniewski a écrit :
Hello,

2012/11/19 Jacky Carimalo <jacky.carim...@univ-nantes.fr <mailto:jacky.carim...@univ-nantes.fr>>

    Le 19/11/2012 12:00, Alan Brown a écrit :
    > On 19/11/12 11:04, Jacky Carimalo wrote:
    >> Hello,
    >> I have the same problem.
    >> Bacula stopped filling a tape after 4 errors, as described below !
    >> I would like to be able to tell it to continue ...
    > update Volume={name} VolStatus=append
    >
    >
    I did :

    update Volume={name} VolStatus=append

    but it then marked the volume Used, and not enabled for backup on it
    again, keeping its first data.


Is LTP102L1 a tape volume? If so why did you define a Max Volume Jobs on this kind of volume?

best regards
Radek


    *messages
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Start Backup
    JobId 12075,
    Job=Backup_gromel1d.univ-nantes.prive_di_LTO.2012-11-19_15.42.45_04
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Volume used
    once. Marking Volume "LTP102L1" as Used.
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Using Device
    "OVL_LTO-3_Drive-1"
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: No slot
    defined
    in catalog (slot=0) for Volume "Vol_gromel_6393" on
    "OVL_LTO-3_Drive-1"
    (/dev/st1).
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Cartridge
    change or "update slots" may be required.
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Warning:
    mount.c:217 Open device "OVL_LTO-3_Drive-1" (/dev/st1) Volume
    "Vol_gromel_6393" failed: ERR=dev.c:513 Unable to open device
    "OVL_LTO-3_Drive-1" (/dev/st1): ERR=Aucun medium trouvé

    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: No slot
    defined
    in catalog (slot=0) for Volume "Vol_gromel_6393" on
    "OVL_LTO-3_Drive-1"
    (/dev/st1).
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Cartridge
    change or "update slots" may be required.
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Warning:
    mount.c:217 Open device "OVL_LTO-3_Drive-1" (/dev/st1) Volume
    "Vol_gromel_6393" failed: ERR=dev.c:513 Unable to open device
    "OVL_LTO-3_Drive-1" (/dev/st1): ERR=Aucun medium trouvé

    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: No slot
    defined
    in catalog (slot=0) for Volume "Vol_gromel_6393" on
    "OVL_LTO-3_Drive-1"
    (/dev/st1).
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Cartridge
    change or "update slots" may be required.
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Warning:
    mount.c:217 Open device "OVL_LTO-3_Drive-1" (/dev/st1) Volume
    "Vol_gromel_6393" failed: ERR=dev.c:513 Unable to open device
    "OVL_LTO-3_Drive-1" (/dev/st1): ERR=Aucun medium trouvé

    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: No slot
    defined
    in catalog (slot=0) for Volume "Vol_gromel_6393" on
    "OVL_LTO-3_Drive-1"
    (/dev/st1).
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Cartridge
    change or "update slots" may be required.
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Warning:
    mount.c:217 Open device "OVL_LTO-3_Drive-1" (/dev/st1) Volume
    "Vol_gromel_6393" failed: ERR=dev.c:513 Unable to open device
    "OVL_LTO-3_Drive-1" (/dev/st1): ERR=Aucun medium trouvé

    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: No slot
    defined
    in catalog (slot=0) for Volume "Vol_gromel_6393" on
    "OVL_LTO-3_Drive-1"
    (/dev/st1).
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Cartridge
    change or "update slots" may be required.
    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Warning:
    mount.c:217 Open device "OVL_LTO-3_Drive-1" (/dev/st1) Volume
    "Vol_gromel_6393" failed: ERR=dev.c:513 Unable to open device
    "OVL_LTO-3_Drive-1" (/dev/st1): ERR=Aucun medium trouvé

    19-nov. 15:42 bacula.u11.univ-nantes.prive- JobId 12075: Please mount
    Volume "Vol_gromel_6393" or label a new one for:
         Job:
    Backup_gromel1d.univ-nantes.prive_di_LTO.2012-11-19_15.42.45_04
         Storage:      "OVL_LTO-3_Drive-1" (/dev/st1)
         Pool:         Pool_gromel_LTO
         Media type:   LTO-3


    
------------------------------------------------------------------------------
    Monitor your physical, virtual and cloud infrastructure from a single
    web console. Get in-depth insight into apps, servers, databases,
    vmware,
    SAP, cloud infrastructure, etc. Download 30-day Free Trial.
    Pricing starts from $795 for 25 servers or applications!
    http://p.sf.net/sfu/zoho_dev2dev_nov
    _______________________________________________
    Bacula-users mailing list
    Bacula-users@lists.sourceforge.net
    <mailto:Bacula-users@lists.sourceforge.net>
    https://lists.sourceforge.net/lists/listinfo/bacula-users




--
Radosław Korzeniewski
rados...@korzeniewski.net <mailto:rados...@korzeniewski.net>


------------------------------------------------------------------------------
Monitor your physical, virtual and cloud infrastructure from a single
web console. Get in-depth insight into apps, servers, databases, vmware,
SAP, cloud infrastructure, etc. Download 30-day Free Trial.
Pricing starts from $795 for 25 servers or applications!
http://p.sf.net/sfu/zoho_dev2dev_nov


_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users


--
Jacky CARIMALO
Université de Nantes
Direction des Systèmes d'Information
Tel : 02 53 48 49 22 (en interne : 22 49 22)
Fax : 02 53 48 49 09

------------------------------------------------------------------------------
Monitor your physical, virtual and cloud infrastructure from a single
web console. Get in-depth insight into apps, servers, databases, vmware,
SAP, cloud infrastructure, etc. Download 30-day Free Trial.
Pricing starts from $795 for 25 servers or applications!
http://p.sf.net/sfu/zoho_dev2dev_nov
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to