On 6/13/2011 2:15 AM, Mike Seda wrote:
I forgot to mention that during my debugging, I did have "Heartbeat Interval" set to 10 on the Client, Storage, and Director resources. The same error still occurred... Very odd.
I have encountered similar situations with clients. Everything but Bacula would appear to work over the network, but Bacula would fail. In one case it was a bad switch, and 2 or 3 other times it was a bad NIC in the client. My conclusion is that Bacula is very sensitive to network problems, and since it is network heavy during a backup, it tends to reveal network problems when nothing else does. If the client has been working in the past, then suddenly began failing jobs, then the problem is not likely the config. The procedure I now go through to diagnose client problems is something like:
1) If a win32 client, then disable OS power management (can turn off NIC's PHY inappropriately)
2) Swap connections with an existing, known working client (if possible) 3) Replace Ethernet patch cable 4) Connect client to a different switch (if possible) 5) Replace client's NIC 6) Try different plenum cabling or bypass plenum cabling if possible7) Physically move client and directly connect to the switch SD is connected to
For me, this error has always thus far ended up being a hardware problem.
------------------------------------------------------------------------------ EditLive Enterprise is the world's most technically advanced content authoring tool. Experience the power of Track Changes, Inline Image Editing and ensure content is compliant with Accessibility Checking. http://p.sf.net/sfu/ephox-dev2dev
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users