I just had a very odd (and rather alarming, for a few minutes) event happen.
Five days ago, I received a new box of blank LTO2 tapes. On Sunday, I deleted the first six old LTO1 tapes from my FULL-TAPE pool and labelled six of the new LTO2 tapes, ARCH-0001 through ARCH-0006, in preparation for the full backups scheduled to begin at 0430 yesterday. The backups ran rather slowly, writing three tapes, ARCH-0001 through ARCH-0003, before eventually stalling at the writing-attributes stage. (I think I know why that happened. I'll come back to that later.) Late this morning, I eventually killed the stalled backups, deleted the jobs, purged the three tapes used, and marked them RECYCLE. Then I restarted MySQL and Bacula (more on that later), then restarted all the backups, by hand. The smaller backups ran to completion fine; the main server backup filled the first LTO2 tape not long ago and requested a second tape. It requested ARCH-0004, as ARCH-0004 is the first completely unused appendable volume. I have it set to ACCEPT ANY VOLUME, so I loaded the correct tape, ARCH-0002, and clicked Mount in BAT. This is where I had an adrenaline-rush moment, because after mounting the tape BAT storage daemon status reported the storage daemon as mounted WITH ARCH-0004. I double-checked to ensure that I had physically inserted ARCH-0002 into the drive, and sure enough, it was. The display did not update to correctly show the mounted volume as ARCH-0002 until Bacula wrote the first 5GB "file" to the tape. That gave me a few bad minutes. I did NOT want to have to kill the full backup and start it over. (The first tape always seems to be slow to fill, because many small files are written to it. It took seven hours to write 226GB of data to the first tape, an average of about half a gigabyte per minute. By the time Bacula gets into the second tape, it's into the big storage array which mostly contains multi-megabyte to multi-gigabyte files, and it's now writing about 1.3GB/minute.) Now, I said I'd get back to the MySQL issues. I was reading through some documents about mySQL on ZFS, and came across (again) a recommendation from one MySQL tester that reported the best MySQL performance from setting the InnoDB buffer pool small, 100MB or so, and allowing ZFS to do the data caching. And I thought, "You know, I don't believe I've ever tried this. I'll give it a shot and see how it goes." Well, after trying this, I can now definitively state: DO NOT DO THIS IF YOUR BACULA CATALOG IS ON MYSQL. It may well work well for general usage, but for Bacula, this configuration trick DOES NOT WORK. If you are using Bacula with a MySQL catalog database on ZFS, configure MySQL as you would if it were NOT on ZFS. Do NOT rely on the "let ZFS cache the data" trick, because it won't work with Bacula. -- Phil Stracchino, CDK#2 DoD#299792458 ICBM: 43.5607, -71.355 ala...@caerllewys.net ala...@metrocast.net p...@co.ordinate.org Renaissance Man, Unix ronin, Perl hacker, SQL wrangler, Free Stater It's not the years, it's the mileage. ------------------------------------------------------------------------------ Colocation vs. Managed Hosting A question and answer guide to determining the best fit for your organization - today and in the future. http://p.sf.net/sfu/internap-sfd2d _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users