> I noticed every time I have to cancel a running job, the tape/volume > goes into error state. I assumed the job would terminate gracefully > with an eod mark but seems not. Is there a way I can put an eod mark > and put the tape back to append mode? I am running version 2.2.6 on > RHEL 4.6 server (64 bit). >
This bug was fixed in version 5.0.3. Its not about EOD marks but the catalog thinking there is 1 more file on the tape than it has recorded in the database. You have to correct this in the database to fix the inconsistency. Then mark the tape as append and you should be able to use the tape. I did that a few times in the past. The logs should mention this in marking the tape as error. John ------------------------------------------------------------------------------ What You Don't Know About Data Connectivity CAN Hurt You This paper provides an overview of data connectivity, details its effect on application quality, and explores various alternative solutions. http://p.sf.net/sfu/progress-d2d _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users