On Fri, Apr 16, 2010 at 2:03 PM, Tomasz Gorny <tg...@wp.pl> wrote: > Hello, > > I'm using bacula some time. After moving to new hardware I've this > problem: > > ========== > 16-Apr 19:55 backup01_dir JobId 11745: Using Device "PV124T-LT03" > 16-Apr 19:55 backup01_sd JobId 11745: 3301 Issuing autochanger "loaded? > drive 0" command. > 16-Apr 19:55 backup01_sd JobId 11745: 3302 Autochanger "loaded? drive > 0", result: nothing loaded. > 16-Apr 19:55 backup01_sd JobId 11745: 3304 Issuing autochanger "load > slot 1, drive 0" command. > * > * > You have messages. > *mess > 16-Apr 19:56 backup01_sd JobId 11745: 3305 Autochanger "load slot 1, > drive 0", status is OK. > 16-Apr 19:56 backup01_sd JobId 11745: Error: dev.c:474 Unable to open > device "PV124T-LT03" (/dev/nst0): ERR=No medium found > 16-Apr 19:56 backup01_sd JobId 11745: Recycled volume "000034L3" on > device "PV124T-LT03" (/dev/nst0), all previous data lost. > > Can you advice ? >
You may need to tailor your mtx-changer script to your drive. It looks like mtx-changer said the tape was loaded and returned but the tape was not finished. Then in the same minute the tape was finished and bacula continued. John ------------------------------------------------------------------------------ Download Intel® Parallel Studio Eval Try the new software tools for yourself. Speed compiling, find bugs proactively, and fine-tune applications for parallel performance. See why Intel Parallel Studio got high marks during beta. http://p.sf.net/sfu/intel-sw-dev _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users