Hello, 26.11.2009 16:31, Juergen Koch wrote: > I use a autochanger with bacula on debian/lenny. > The changer has two drives and I can load tapes into the drives using > the mtx-script: > > mtx-changer /dev/sg4 load 2 /dev/nst1 1 > > But, the mount-command use only the default tape values: > > ----- > *mount > Automatically selected Catalog: MyCatalog > Using Catalog "MyCatalog" > Automatically selected Storage: tl-01 > Connecting to Storage daemon tl-01 at bacula:9103 ... > > Enter autochanger drive[0]: 1 ---!!!!--- > > Enter autochanger slot: 2 > 3307 Issuing autochanger "unload slot 1, drive 0" command. > 3304 Issuing autochanger "load slot 2, drive 0" command. > 3305 Autochanger "load slot 2, drive 0", status is OK. > 3001 Mounted Volume: xxx > 3001 Device "tl-01-1" (/dev/nst0) is already mounted with Volume "xxx" > ----
Looks like a bug to me, unless you misconfigured something inthe SD.conf. Post that autochangers configuration, and also mention the version you're using, and we might have some advice for you! Cheers, Arno > The parameters to the mtx-script in the example are: > > ----- > > /dev/sg6 unload 1 /dev/nst0 0 > > /dev/sg6 load 2 /dev/nst0 0 > > ---- > > so, I can't load tapes to drive two (Drive Index = 1) > > any hints? > > is this a bug in the mount-command? -- Arno Lehmann IT-Service Lehmann Sandstr. 6, 49080 Osnabrück www.its-lehmann.de ------------------------------------------------------------------------------ Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day trial. Simplify your report design, integration and deployment - and focus on what you do best, core application coding. Discover what's new with Crystal Reports now. http://p.sf.net/sfu/bobj-july _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users