>>>>> On Wed, 29 Apr 2009 16:45:17 +0200, SZÉKELYI Szabolcs said:
> 
> Hi,
> 
> We configured our tape storage with
> 
> Two EOF = Yes
> BSF at EOM = Yes
> 
> and found that this works fine as long as the tape is not ejected and
> reloaded. After that, Bacula complains about number of files on the
> volume not matching that recorded in the catalog.

What is the number of files on the volume and the catalog in the error
message?


> We ran bscan on the volume, it gave the same number of files as the
> catalog had.
> 
> Btape test runs without errors.
> 
> Is this a bug in Bacula or in our thinking? :)

Which operating system and version of Bacula?

__Martin

------------------------------------------------------------------------------