From the User Manual for the MSL6000 series, but should be also for MSL5000 series.....
100F SCSI Un-terminated Resets (SCSI Continuous Resets Detected) • Verify that the library SCSI bus is properly terminated. • Update the Map using the LCD touch display. (Menu -> Maintenance -> Force reconfiguration) Likely, the SCSI bus is not terminated properly or you have a defective SCSI cable or terminator. Kern Sibbald wrote: > Hello, > > The proper way to resolve this problem is to discuss it on the bacula-users > list as recommended at: http://www.bacula.org -> Support. Then if they > believe that it is a software error (impossible for me to determine from what > you have provided since there is no Bacula output provided), you would > proceed to write up a bug report: http://www.bacula.org -> Bugs > > This may be related to bug #1032, and if it is, it would not be useful to > open > a new bug report but could potentially be useful to add to that bug. > > With the information presented here, it looks to me like a hardware problem, > an mtx problem, or possibly some manifestation of bug #1032. > > Regards, > > Kern > > > On Monday 14 January 2008 17:18, Thorsten Luft wrote: > >> Hi Kern, >> >> we use a HP MSL-5030 Libraray with 2 LTO2 drive >> >> debian4 >> with bacula-2.2.7 >> and following Patches: >> >> 2.2.7-jobdefs-migtype >> 2.2.7-reserve >> >> Errorcode on Display: 100F >> >> >> [EMAIL PROTECTED]:~# mtx -f /dev/sg2 status >> mtx: Request Sense: Long Report=yes >> mtx: Request Sense: Valid Residual=no >> mtx: Request Sense: Error Code=0 (Unknown?!) >> mtx: Request Sense: Sense Key=No Sense >> mtx: Request Sense: FileMark=no >> mtx: Request Sense: EOM=no >> mtx: Request Sense: ILI=no >> mtx: Request Sense: Additional Sense Code = 00 >> mtx: Request Sense: Additional Sense Qualifier = 00 >> mtx: Request Sense: BPV=no >> mtx: Request Sense: Error in CDB=no >> mtx: Request Sense: SKSV=no >> INQUIRY command Failed >> >> This Software-Error occur one time in a week. The Library and bacula-SD >> reset and doesnt help. I have to restart bacula completly. >> >> This occur also with version 2.2.6 with an other Software-Error on the >> MSL-Display. >> >> Do you have a solution? >> >> Thanks in advanced >> >> Thorsten Luft >> >> PS: I only read the bacula-developer-list on gmame >> > > ------------------------------------------------------------------------- > This SF.net email is sponsored by: Microsoft > Defy all challenges. Microsoft(R) Visual Studio 2008. > http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/ > _______________________________________________ > Bacula-users mailing list > Bacula-users@lists.sourceforge.net > https://lists.sourceforge.net/lists/listinfo/bacula-users > ------------------------------------------------------------------------- This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008. http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/ _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users