Hello,

Since a few days I get "Block checksum mismatch" errors when trying to restore.
I run bacula nearly a year now, I have done successfull restore jobs before.
btape test completes successfull.


Errors looks like this:
19-Dec 08:29 bs1-sd JobId 3242: Error: block.c:318 Volume data error at 33:9495!
Block checksum mismatch in block=9495 len=64512: calc=88d085a3 blk=cb1338f1

Next try:
19-Dec 11:33 bs1-sd JobId 3245: Error: block.c:318 Volume data error at 33:9495!
Block checksum mismatch in block=9495 len=64512: calc=5218e505 blk=cb1338f1

Sometimes the error is on the same block, but with other calc value, another 
time
I get the errors at a complete different block.

The error appears with new tapes and with tapes being in use some month now.
And yes, I have cleaned the drive with the cleaning tape.

I'm using bacula 2.2.5 (debian-backports packages) on Debian Etch
Tape drive is a SONY SDX-700C in an autochanger tape library SONY LIB-162.

Regards,
Henry

-------------------------------------------------------------------------