> [EMAIL PROTECTED] wrote: >> Hi, >> >> I have a Spectra Logic T50 and run about 50 jobs each night. The tape >> library has 2 LTO3 drives. Lately it seems like at the beginning of the >> night, one of the jobs will sit and and keep a drive waiting for a >> volume >> all night: >> >> 07-Dec 02:24 escabot-sd JobId 8280: Please mount Volume "000097LX" or >> label a new >> one for: >> Job: espizarro.2007-12-07_02.00.55 >> Storage: "T50-Drive-1" (/dev/nst0) >> Pool: Daily >> Media type: LTO-3 > > Was the volume being requested, 000097LX, already mounted on the other > tape > drive, nst1? If so, it sounds like you're hitting the same glitch I ran > into: > > http://bugs.bacula.org/view.php?id=1018 >
Yeah, seems to be the same problem. I haven't actually watched to see if the other drive is requesting the tape at the same time, but I assumed that it was something like that. Its also at the beginning of the jobs, so that sounds right. I guess they don't have any ETA -- I'm also using version 2.2.6. --Marc > -- > Frank Sweetser fs at wpi.edu | For every problem, there is a solution > that > WPI Senior Network Engineer | is simple, elegant, and wrong. - HL > Mencken > GPG fingerprint = 6174 1257 129E 0D21 D8D4 E8A3 8E39 29E3 E2E8 8CEC > > !DSPAM:1,47595342206877771210147! > > ------------------------------------------------------------------------- SF.Net email is sponsored by: Check out the new SourceForge.net Marketplace. It's the best place to buy or sell services for just about anything Open Source. http://sourceforge.net/services/buy/index.php _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users