Hi,

Arno Lehmann wrote:

> Run it several times with different slot ranges, like
> 'label barcodes slots=1-3 pool=F01' and so on.

Brilliant - thank you. The fact that you can use slots and pool seems to 
be missing from the docs, so I guess I should work on trying to add it :)

> 
>> It only seems to want to allow me to put the tapes into 
>> a single pool. I could allow it to put everything into the default pool 
>> but there doesn't seem to be a way of moving volumes to a different pool 
>> with 'add' and 'delete' of each one which is a bit of a pain.
> 
> Use 'update volume=F01T01L4 pool=F01' and so on. Or use the menu after 
> 'update volume=F01T01L4', of course.

Ah great too, very useful :)

Thank you.

-------------------------------------------------------------------------