Hi,

29.10.2007 22:51,, x x wrote::
> Hello,
> I've a problem with watchdog timer in bacula .
> My autochangger load tape longer then 5 min. After this time (5min) 
> bacula give my this message
> 
> Autochanger "loaded? drive 0", result is Slot 1896.

Nice big thing... what hardware is this?

> 29-pa
> 
> Ľ 17:10 ls90v10-sd: ls90v02-archivK.2007-10-29_17.05.01 Fatal error: 
> 3992 Bad autochanger "load slot 335, drive 0": ERR=Child died from 
> signal 15: Termination.
> 
> Results=Program killed by Bacula watchdog (timeout)
> 
> Can I use specified timeout ? Where i can chcange this ?

In the SD configuration, device resource, "Maximum Changer Wait" 
directive.

It's in the manual, of course :-)

Arno

> Regards,
> 
> Jakub Szefler
> 
>  
> 
>  
> 
> 
> ------------------------------------------------------------------------
> 
> -------------------------------------------------------------------------
> This SF.net email is sponsored by: Splunk Inc.
> Still grepping through log files to find problems?  Stop.
> Now Search log events and configuration files using AJAX and a browser.
> Download your FREE copy of Splunk now >> http://get.splunk.com/
> 
> 
> ------------------------------------------------------------------------
> 
> _______________________________________________
> Bacula-users mailing list
> Bacula-users@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/bacula-users

-- 
Arno Lehmann
IT-Service Lehmann
www.its-lehmann.de

-------------------------------------------------------------------------
This SF.net email is sponsored by: Splunk Inc.
Still grepping through log files to find problems?  Stop.
Now Search log events and configuration files using AJAX and a browser.
Download your FREE copy of Splunk now >> http://get.splunk.com/
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to