Hi, I've been struggling with Bacula for a single backup installation for
almost 4 months now. Although installation and configuration are well documented I'm still confused by two problems we can't get solved: 1. Even with brand new tapes, on two different tape drives, using continuous cleaning cycles, the tapes that used to store between 11.5 and 13 GB uncompressed data on a windows machine only take about 8 GB using bacula (same drive, same tapes). Following the advice to switch off software compression when hardware compression is enabled, we run tests with following results (always the same fileset of 23 GB uncompressed data) hw-compress sw-compress spool size data/tape total # of tapes used on on 14 GB 8.2 GB 1.7 on off 23 GB 12.9 GB 1.8 so we use the installation with both sw and hw compression turned on, as it gives us better performance and less tapes/backup. Why is it impossible to store more then 8 GB on a 12/24GB tape. Again: we ran the tests on multiple different drives (HP15xx and Sony DDS3-drives). 2. Up to now a verify at level "VolumeToCatalog" always (!) brings up at least one error of the type "Error: block.c:317 Volume data error at 3:2817! Block checksum mismatch in block=2817 len=64512: calc=8fe728a4 blk=bd217fe3" in the middle of the tape. After that bacula dupms the whole remaining file list into an email message of about 30MB in size. - Is there any way to make Bacula stop to send the file list while keep on sending email notifications ? - How can it be, that a single error renders the whole tape of a backup useless ? Why does bacula not continue to verify the other 80% of a backup and tells something like "block error while reading ..., missing files ...." ? Thanks for any hints, Carsten The installation I'm talking about runs on a 2.0.36 Linux kernel with a single Sony SCSI DDS3 tape drive (12GB uncompressed) inside a 8-slot auto-changer (drive and changer are the only devices on the SCSI bus) The team drive+changer work together as expected. We run about ten other backup installations using commercial tools and Amanda. So far, bacula was the one easiest to set up among the free tools, but after 4 month of testing we haven't got single backup which runs through and verifies without an error. I know, that DDS is not the idal choice as we run some SLR, LTO and VXA solutions, but for that particular case the tape drive has to be DDS3 as the customer in question has a large library which only handles DDS and MiniDV tapes. -- -------------------------------------------------- Yoo GmbH Tel.: 037 328 809 40 Zellwaldring 51 Fax : 0351 79 79 900 D-09603 Grossvoigtsberg Germany www.yoogmbh.de Registereintrag: Amtsgericht Chemnitz, HRB 181 852 Geschäftsführung: Carsten Ralle -------------------------------------------------- ------------------------------------------------------------------------- This SF.net email is sponsored by: Splunk Inc. Still grepping through log files to find problems? Stop. Now Search log events and configuration files using AJAX and a browser. Download your FREE copy of Splunk now >> http://get.splunk.com/ _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users