Hello,

I have just released Bacula BETA 1.39.32 source tar file and the Windows 
binary installer to their respective beta sections of the Source Forge Bacula 
release area.

This release is primarily a bug fix release -- it in fact fixes a number of 
important bugs, some of which appear in version 1.38.11.  

This is very likely to be the last beta release prior to the official 1.40.0 
release.  There are a few "minor" bugs and some documentation issues that I 
will work on in the mean time.  If all goes well the official release will be 
shortly after Christmas.

Best regards,

Kern

ChangeLog entries since the prior BETA release:

Version 1.39.32 released:
20Dec06
kes  Take first catalog if gui is set, or if using dotcmd.
kes  Fix a couple of compiler warnings in wx-console
kes  Apply the immutable patch for FreeBSD hard linked files supplied
     by Olivier Lehmann.
kes  Add Volume name to Forward spacing message.
kes  Update migration job start time (so it is not zero) to prevent
     immediate recycling of the job.  This *should* fix bug #733.
19Dec06
ebl  Fix runscript configuration parsing bug.
17Dec06
kes  Add ENABLE_NLS (as suggested by Eric) to correct NLS problems.
     Remove NLS kludge from baconfig.h.  This fixes bug #729.
kes  Allow seeking on DVD.
kes  Add additional messages when Job canceled automatically for
     max run time or max start wait exceeded.  This fixes bug #621.
kes  Update maxruntime-test in regression script to properly test
     max run time -- from info given in bug #621.
kes  Simplify automatic cancel code.
kes  Add check for job_canceled() in FD when contacting SD so that if
     job is canceled from max runtime, it terminates faster.
16Dec06
kes  Save and restore volume name in stored/mount.c fixed bug #712
     where wrong tape was requested in a mount.
kes  Implement cleaner orphan buffer dumping with buf address.
kes  Fix orphaned buffer when canceling job waiting on op intervention.
kes  Update projects file for next vote.
kes  Implement a fix (more could be done) for bug #728 where a double
     EOF is writing on the Volume when spooling is enabled and the
     connection with the FD fails (FD crash, comm error).
kes  Disable attempting to autolabel when polling and device is not
     a tape. This fixes bug #730 where polling with a removable disk
     not mounted caused lots of new Volumes to be created then marked
     in error.
15Dec06
kes  Enable VSS by default.


Version 1.39.30 released: 14Dec06
...

-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys - and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to