On 29 Jun 2006 at 11:57, kiryl wrote:

> Hey guys,
> i have been using bacula for a while now, works great.
> Rescently i have purchased PowerVault 124T, upgraded bacula to 1.38.10
> 
> Here is what i get when i try to do "label barcodes"
> Connecting to Storage daemon DLT at backuppc:9103 ...
> Sending label command for Volume "MER608S3" Slot 1 ...
> 3301 Issuing autochanger "loaded drive 0" command.
> 3302 Autochanger "loaded drive 0", result: nothing loaded.
> 3304 Issuing autochanger "load slot 1, drive 0" command.
> 3305 Autochanger "load slot 1, drive 0", status is OK.
> 3301 Issuing autochanger "loaded drive 0" command.
> 3302 Autochanger "loaded drive 0", result is Slot 1.
> block.c:945 Read error at file:blk 0:0 on device "DLT-VS160-1" 
> (/dev/nst0). ERR=Input/output error.
> 3000 OK label. Volume=MER608S3 Device="DLT-VS160-1" (/dev/nst0)
> Catalog record for Volume "MER608S3", Slot 1  successfully created.
> 
> after that volume can be used and bakups goes fine.... should i be worry?

That is a normal labelling event.  Nothing to be concerned about.

-- 