Bacula was working perfectly before I upgraded from 
app-backup/bacula-1.36.3-r1 to version 1.38.5.

I have a Sony tape changer (LIB-81) with 8 slots and an AIT3 drive.

My problem is that when I issure an "update slots scan", I have :

*update slots scan
Using default Catalog name=MyCatalog DB=bacula
The defined Storage resources are:
     1: File
     2: Sony
Select Storage resource (1-2): 2
Connecting to Storage daemon Sony at orval:9103 ...
3306 Issuing autochanger "slots" command.
Device "SonyDrive" has 8 slots.
Connecting to Storage daemon Sony at orval:9103 ...
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result is Slot 7.
3307 Issuing autochanger "unload slot 7, drive 0" command.
3306 Issuing autochanger "list" command.
Connecting to Storage daemon Sony at orval:9103 ...
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result: nothing loaded.
No VolName for Slot=1 InChanger set to zero.
Connecting to Storage daemon Sony at orval:9103 ...
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result: nothing loaded.
No VolName for Slot=2 InChanger set to zero.
Connecting to Storage daemon Sony at orval:9103 ...
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result: nothing loaded.
No VolName for Slot=3 InChanger set to zero.
Connecting to Storage daemon Sony at orval:9103 ...
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result: nothing loaded.
No VolName for Slot=4 InChanger set to zero.
Connecting to Storage daemon Sony at orval:9103 ...
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result: nothing loaded.
No VolName for Slot=5 InChanger set to zero.
Connecting to Storage daemon Sony at orval:9103 ...
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result: nothing loaded.
No VolName for Slot=6 InChanger set to zero.
Connecting to Storage daemon Sony at orval:9103 ...
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result: nothing loaded.
No VolName for Slot=7 InChanger set to zero.
Connecting to Storage daemon Sony at orval:9103 ...
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result: nothing loaded.
No VolName for Slot=8 InChanger set to zero.

And all my tapes in changer get the flag "In Changer" to 0.

I don't want bacula to use the List command. Why Bacula is not loading the 
next tape before trying to identify it ? 

As I have no barcode reader, here is the results of mtx status and mtx-changer 
list :

orval bacula # mtx -f /dev/sg1 status
  Storage Changer /dev/sg1:1 Drives, 8 Slots ( 0 Import/Export )
Data Transfer Element 0:Empty
      Storage Element 1:Full
      Storage Element 2:Full
      Storage Element 3:Full
      Storage Element 4:Full
      Storage Element 5:Full
      Storage Element 6:Full
      Storage Element 7:Full
      Storage Element 8:Full
orval bacula # ./mtx-changer /dev/sg1 list
1:
2:
3:
4:
5:
6:
7:
8:
orval bacula #             


I'm a bit lost now... And I don't know what to do.

Did you already had that problem ?

Regards,

Pivert.


-------------------------------------------------------
This SF.Net email is sponsored by xPML, a groundbreaking scripting language
that extends applications into web and mobile media. Attend the live webcast
and join the prime developer group breaking into this new coding territory!
http://sel.as-us.falkag.net/sel?cmd=lnk&kid=110944&bid=241720&dat=121642
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to