Hi,
i have problem to work bacula using exabyte loader...
i try this...
* label
Automatically selected Storage: File
Enter new Volume name: TEST01
Automatically selected Pool: Default
Connecting to Storage daemon File at onca:9103 ...
Sending label command for Volume "TEST01" Slot 0 ...
3910 Unable to open device /dev/st0. ERR=dev.c:289 stored: unable to open device /dev/st0: ERR=Input/output error
if i test utilizing mtx-changer script
work fine....
/etc/bacula/scripts# /etc/bacula/scripts/mtx-changer /dev/sg0 load 1 /dev/st0 0
Doing mtx -f /dev/sg0 load 1 0
my storage configuration is:
Device {
Name = VXA-2 #
Media Type = VXA-2
Archive Device = /dev/st0
AutomaticMount = yes; # when device opened, read it
AlwaysOpen = yes;
RemovableMedia = yes;
RandomAccess = no;
Changer Command = "/etc/bacula/scripts/mtx-changer %c %o %S %a %d"
Changer Device = /dev/sg0
AutoChanger = yes
Alert Command = "sh -c 'tapeinfo -f %c |grep TapeAlert|cat'"
}
# dmesg | grep st0
/dev/ide/host0/bus0/target0/lun0: p1 p2 p3 p4
Attached scsi tape st0 at scsi3, channel 0, id 1, lun 0
st0: try direct i/o: yes (alignment 512 B), max page reachable by HBA 1048575
Anybody help me?
Thanks,
--
Tiago Vilas Boas
MCSO,LPIC-2,LPIC-1
- [Bacula-users] Problems use "label" command Tiago Vilas Boas
- Re: [Bacula-users] Problems use "label" co... Arno Lehmann
- Re: [Bacula-users] Problems use "label" co... Maria McKinley