Hi,
I've a strange error using an IBM 3582 autocharger, with 2 LTO-3 drive:
13-Apr 15:20 srvbacula-sd JobId 387: Error: Unable to position to end of
data on device "IBM-tape1" (/dev/IBMtape1): ERR=dev.c:966 ioctl MTIOCGET
error on "IBM-tape1" (/dev/IBMtape1). ERR=Success.
13-Apr 15:20 srvbacula-sd JobId 387: Marking Volume "A00029L3" in Error in
Catalog.
13-Apr 15:20 srvbacula-sd JobId 387: 3307 Issuing autochanger "unload slot
7, drive 0" command.
I've just updated the firmware on both drives (93G6), but the problem still
remain . also I've tried to modify next parameters in Device section of
bacula-sd.conf, with no success:
Two Eof = yes
#Fast Forward Space File = no
#Hardware End of Medium = no
BSF at EOM = yes
Had someone this problem ?
Bye,
Francesco Doni
------------------------------------------------------------------------------