Hello,

I have chan_ss7 0.9 running with an Ericsson mobile switch.

I had use_connect=no first, but sometimes I got IAM messages with the following bit set:

Continuity Check Indicator: Continuity check performed on a previous circuit (0x02)

The result was that the Ericsson Switch sent a Circuit Reset directly after the ACM, which didn't look different to me compared with traces of working calls.

So I tried setting use_connect=yes which solved the problem. But now I get warnings:

WARNING[26068]: l4isup.c:2971 process_cot: Received COT, but state is not ST_CONCHECK for CIC=25?!?


With version 0.9 I also see alot of these:

WARNING[614]: channel.c:2380 set_format: Unable to find a codec translation path from alaw to unknown

If someone has an idea how to fix this, please share your comments.

Best regards,

Marc
_______________________________________________
--Bandwidth and Colocation provided by Easynews.com --

asterisk-ss7 mailing list
To UNSUBSCRIBE or update options visit:
  http://lists.digium.com/mailman/listinfo/asterisk-ss7

Reply via email to