fix the wrong fan speed in fan1_input when the fan control mode is manual.
the fan speed value is not correct when we set manual mode to fan1_enalbe - 1.
since the fan speed in the metrics table always reflects the real fan speed,we
can fetch the fan speed for both auto and manual mode.

Signed-off-by: Kenneth Feng <kenneth.f...@amd.com>
---
 .../gpu/drm/amd/pm/swsmu/smu11/sienna_cichlid_ppt.c   | 11 +++--------
 1 file changed, 3 insertions(+), 8 deletions(-)

diff --git a/drivers/gpu/drm/amd/pm/swsmu/smu11/sienna_cichlid_ppt.c 
b/drivers/gpu/drm/amd/pm/swsmu/smu11/sienna_cichlid_ppt.c
index 496abc31b07e..27b6cade9ade 100644
--- a/drivers/gpu/drm/amd/pm/swsmu/smu11/sienna_cichlid_ppt.c
+++ b/drivers/gpu/drm/amd/pm/swsmu/smu11/sienna_cichlid_ppt.c
@@ -1171,14 +1171,9 @@ static int sienna_cichlid_get_fan_speed_rpm(struct 
smu_context *smu,
        if (!speed)
                return -EINVAL;
 
-       switch (smu_v11_0_get_fan_control_mode(smu)) {
-       case AMD_FAN_CTRL_AUTO:
-               return sienna_cichlid_get_smu_metrics_data(smu,
-                                                          
METRICS_CURR_FANSPEED,
-                                                          speed);
-       default:
-               return smu_v11_0_get_fan_speed_rpm(smu, speed);
-       }
+       return sienna_cichlid_get_smu_metrics_data(smu,
+                                               METRICS_CURR_FANSPEED,
+                                               speed);
 }
 
 static int sienna_cichlid_get_fan_parameters(struct smu_context *smu)
-- 
2.17.1

_______________________________________________
amd-gfx mailing list
amd-gfx@lists.freedesktop.org
https://lists.freedesktop.org/mailman/listinfo/amd-gfx

Reply via email to