[AMD Official Use Only - AMD Internal Distribution Only] Hi Tomasz, We can only have zero rpm on/off setting. After confirmation, the fan stop temperature setting is not exposed to algin windows driver. So the fw always pick the default value. I know it may be not reasonable but it is the truth. Thanks.
-----Original Message----- From: Tomasz Pakuła <tomasz.pakula.oficja...@gmail.com> Sent: Tuesday, March 25, 2025 5:09 AM To: Feng, Kenneth <kenneth.f...@amd.com> Cc: Alex Deucher <alexdeuc...@gmail.com>; Deucher, Alexander <alexander.deuc...@amd.com>; Wang, Yang(Kevin) <kevinyang.w...@amd.com>; amd-gfx@lists.freedesktop.org Subject: Re: [PATCH 2/2] drm/amd/pm: add zero RPM stop temp OD setting support for SMU 14.0.2 Caution: This message originated from an External Source. Use proper caution when opening attachments, clicking links, or responding. On Thu, 20 Mar 2025 at 03:38, Feng, Kenneth <kenneth.f...@amd.com> wrote: > > [AMD Official Use Only - AMD Internal Distribution Only] > > Thanks Tohmasz. > I confirmed that this change is not in the latest driver-if file. > However, this is a fw interface provided by firmware team, we can not change > it. > That means the interface is different between the smu13 and smu14. > Let me check and get back to you. Hi! Just checking in if you had the time to follow up with firmware. Although it works without issues, if there's a need to wait a long time to get this confirmed maybe I should just split this into two separate patches and we could get at least the Zero RPM on/off setting merged? Thanks, Tomasz