On Mon, Mar 20, 2017 at 12:29:56 +0000, Tobias Köck wrote:
> Hi,
>
> I get an error about retention-tapes with Amanda 4.4.3. Is it a new feature
> added to the build? It did work before.
>
> backup@chronos:~$ amcheck kundenarchiv
> Amanda Tape Server Host Check
> -----------------------------
> ERROR: storage 'kundenarchiv': runtapes is larger or equal to policy
> 'kundenarchiv' retention-tapes
If not specified explicitly, retention-tapes gets calculated as 1 less
than the "tapecycle" setting. What settings do you have for "runtapes"
and "tapecycle" in your config?
(In my current test environment for 3.4.3, I have runtapes=1 and
tapecycle=14; with those values, "amcheck" is happy, and "amadmin
<CONFIG> config" reports a retention-tape value of 13 for the
implicitly-created policy.)
Nathan
----------------------------------------------------------------------------
Nathan Stratton Treadway - [email protected] - Mid-Atlantic region
Ray Ontko & Co. - Software consulting services - http://www.ontko.com/
GPG Key: http://www.ontko.com/~nathanst/gpg_key.txt ID: 1023D/ECFB6239
Key fingerprint = 6AD8 485E 20B9 5C71 231C 0C32 15F3 ADCD ECFB 6239