Title: Re: [AFMUG] Mikrotik Official Limitations
Bill,
Just checked my main PPPoE server (CCR1036). 2735 PPPoE sessions. 504 of those are private IP addresses getting NAT. 1,048,576 connections
--
Best regards,
Mark mailto:m...@mailmt.com
Myakka Technologies, Inc.
www.Myakka.com
------
Monday, March 1, 2021, 11:35:02 AM, you wrote:
|
I have to admit, I don't know that I've looked too much at he number of connections. How many subs does it take to achieve a million connections?
bp
<part15sbs{at}gmail{dot}com>
On 3/1/2021 8:02 AM, Steven Kenney wrote:
|
Still fighting with Mikrotik about the 1072 reboots. New hardware didn't fix it, had several people check the configs all were good. After 2 months of going back and forth, escalating to a higher tier tech... I officially got a response that 1 million connections is too much for the 1072 and I should expect it to reboot and not function properly. That was their conclusion. Even though all of the 72 processors are under 50%, memory usage is only about 20% etc. Turn off connection tracking is the their solution.
How about those apples?
|
|
--
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com