Are you sure this was meant for the AF group?

On Sun, Jul 12, 2020 at 2:50 PM <ch...@wbmfg.com> wrote:

> Excellent job on the intersection guys.  Y’all just keep getting better at
> what you do.
>
> This week Centracom said they are coming to splice and perhaps install
> equipment in the C.O.
> BTW, C.O. stands for Central Office.  Many years ago it was CDO for
> Central Distribution Office.  This is where the telephone operators used to
> manually switch telephone calls with “cord boards”.  Later automatic
> switching equipment took over that job but the C.O. has remained.  Internet
> companies frequently call their main tech office the NOC Network Operations
> Center.  NOC is probably taking over for C.O. but I am an older dude and
> will continue to refer to the C.O.  Ours is so small it would more properly
> be called a Carrier Hut or Remote.  But I digress.
>
> We want everything looking as nice as we can for our upstream provider’s
> visit.
>
> Inside the C.O. we need the following done:
> Racks straightened
> Batteries reversed
> Walls and ceiling washed
> Stairs installed
> Unused wires and equipment removed
> Wires straightened up and dressed better
> Perhaps run the 120 VAC to the inverter input
>
> Outside the C.O. we need the following:
> Back wall painted where the ducts are.
> Box that was over that area removed from the field to the North and either
> saved for repurpose or put in the scrap metal dumpster.
> All weeds removed from the fenced area.
> Gravel covering 100% of that area.
>
> Outside the fenced area we need the following:
> Put all the pieces of that motorhome in the dump trailer.  Any other
> garbage too and take it to the dump.
> Move that motorhome chassis somewhere it is not obvious.
> Clean up, straight up etc the lot.  Make sure all the trucks and such are
> parked in a nice orderly fashion.
> Knock down any weeds and lay down weed killer in those spots.
>
> Need to make sure not to leave the HVAC on in there until we get equipment
> actually needing to be powered.
> Even then, we will want to set it no lower than 90 degrees.  Just got 15
> days worth of power bill (someone had left the AC on down to about 65
> degrees) and the bill was $100.  With no revenue producing customers yet, I
> don’t want recurring expenses.
> --
> AF mailing list
> AF@af.afmug.com
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>


-- 
Lewis Bergman
325-439-0533 Cell
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to