I should say all of the /smaller/ ones use a DC barrel connector and/or PoE.

Here's a DC model....but with fewer ports: https://mikrotik.com/product/crs309_1g_8s_in <https://mikrotik.com/product/crs309_1g_8s_in>

I have not opened up a CRS 317, but the AC powered CCR's all have a 24v power supply inside the case.  What I've been doing is cut the 24v cable, drill a hole in the case, and bring it my own DC supply cable from a meanwell RSD connected to the -48V plant.  I wish they just offered a DC version, but for the money saved I don't mind drilling one hole and splicing two wires together.



On 11/13/2019 11:41 AM, Carl Peterson wrote:
"They're pretty much all DC.....but not -vDC."
Am I just missing something?  when I look at one, i.e https://mikrotik.com/product/crs317_1g_16s_rm it says dual AC inputs.  is there another version with DC?

On Wed, Nov 13, 2019 at 9:15 AM Adam Moffett <dmmoff...@gmail.com <mailto:dmmoff...@gmail.com>> wrote:

    They're pretty much all DC.....but not -vDC.


    On 11/13/2019 10:12 AM, Carl Peterson wrote:
    Do the planet switches double tag (QinQ)? Have a
    similar requirement to replace Ignite switches but they have to
    support DC power, preferably -48. Looked at the mikrotik switches
    but none but the little 6 port support DC!




    On Wed, Nov 13, 2019 at 8:49 AM Adam Moffett <dmmoff...@gmail.com
    <mailto:dmmoff...@gmail.com>> wrote:

        I'll check it out thanks.

        On 11/13/2019 9:47 AM, Sean Heskett wrote:
        Planet industrial version



        On Wed, Nov 13, 2019 at 7:32 AM Adam Moffett
        <dmmoff...@gmail.com <mailto:dmmoff...@gmail.com>> wrote:

            It's hard to argue with those Mikrotik CRS switches for
            what you get for the money, but I have my complaints.

            I'd like to explore other switches with:

              * at least 4 SFP+ ports
              * at least 4 SFP ports
              * DC input
              * Extended temperature range (doesn't have to be -40,
                but does need to operate below freezing)
              * Smallish size (1/4 depth 1U, or possibly DIN rail)

            I have feature wishes too, but just the size and
            temperature spec takes 99% of switches out of the mix. 
            What options are there?  I looked at an Adtran Netvanta
            and loved it.....but the price tag will knock you out of
            your chair. Rather than talk to every switch vendor in
            the world, I wonder if any of you guys already found
            something you like.


-- AF mailing list
            AF@af.afmug.com <mailto:AF@af.afmug.com>
            http://af.afmug.com/mailman/listinfo/af_af.afmug.com


-- AF mailing list
        AF@af.afmug.com <mailto:AF@af.afmug.com>
        http://af.afmug.com/mailman/listinfo/af_af.afmug.com



--
    Carl Peterson

    *PORT NETWORKS*

    401 E Pratt St, Ste 2553

    Baltimore, MD 21202

    (410) 637-3707


-- AF mailing list
    AF@af.afmug.com <mailto:AF@af.afmug.com>
    http://af.afmug.com/mailman/listinfo/af_af.afmug.com



--

Carl Peterson

*PORT NETWORKS*

401 E Pratt St, Ste 2553

Baltimore, MD 21202

(410) 637-3707


-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to