Nate, in my case, I can fit the DC and fiber breakout inside the radio
enclosure, so no need for a splice case:

 



 

Peter Kranz
 <http://www.unwiredltd.com/> www.UnwiredLtd.com
Desk: 510-868-1614 x100
Mobile: 510-207-0000
 <mailto:[email protected]> [email protected]

 

From: AF <[email protected]> On Behalf Of Nate Burke
Sent: Wednesday, June 13, 2018 7:35 PM
To: [email protected]
Subject: Re: [AFMUG] FW: Hybrid fiber/DC cables..

 

I just did my first horizontal deployment of the Shireen cable today, 600'
through conduit, so I could run the splicer on the tailgate.  I'm curious.
how are people terminating this for tower applications?  Pre-terminating it
into a splice case and sending it up all done (Spliced pigtails, or SC/LC
Jacks in a box)?  Making the guy hang off the tower with the splicer?
Something more exotic that I don't know about?  The way our cable are routed
up most sites, I don't have the space to physically pull up a splice case
attached to the cable.  

On 6/13/2018 8:02 PM, Mathew Howard wrote:

well, as long as they can make it faster than you can buy it, it's
practically unlimited...

 

On Wed, Jun 13, 2018 at 7:56 PM, Josh Luthman <[email protected]
<mailto:[email protected]> > wrote:

Unlimited?  You must work for AT&T and HughesNet part time.




 

Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

 

On Wed, Jun 13, 2018 at 6:23 PM, Greg Alberti <[email protected]
<mailto:[email protected]> > wrote:

There is a unlimited supply of 1000' spools and a limited edition of 3200'
spools available in the channel also.

 

v.r.

Greg Alberti

Shireen, Inc.

 

From: AF [mailto:[email protected] <mailto:[email protected]> ]
On Behalf Of Josh Baird
Sent: Wednesday, June 13, 2018 5:52 PM
To: Peter Kranz <[email protected] <mailto:[email protected]> >
Cc: [email protected] <mailto:[email protected]> 
Subject: Re: [AFMUG] FW: Hybrid fiber/DC cables..

 

Yes - we have the Commscope deployed at several sites but now we are
ordering spoils of Shireen FP1204 from Streakwave/Baltic.


On Jun 13, 2018, at 5:30 PM, Peter Kranz <[email protected]
<mailto:[email protected]> > wrote:

Anyone using cabling like this? 2 fiber strands plus 2 12 Gauge copper power
leads?.. I'm not finding good availability on the Commscope product so
curious what people are sourcing.

 

<image001.jpg>

 

https://www.commscope.com/catalog/networking_systems/product_details.aspx?id
=90543

 

Peter Kranz
www.UnwiredLtd.com <http://www.UnwiredLtd.com> 
Desk: 510-868-1614 x100
Mobile: 510-207-0000
[email protected] <mailto:[email protected]> 

 

-- 
AF mailing list
[email protected] <mailto:[email protected]> 
http://af.afmug.com/mailman/listinfo/af_af.afmug.com


-- 
AF mailing list
[email protected] <mailto:[email protected]> 
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

 


-- 
AF mailing list
[email protected] <mailto:[email protected]> 
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

 





 

-- 
AF mailing list
[email protected]
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to