Sujay What is the make and model of the new library and what version of TSM server are you running. Have you checked that the version of server you have supports your new library ?
For Instance, the new IBM TS3310 is only supported a TSM versions 5.2.7.x and 5.3.2.x and above. Support matrix can be found at http://www-306.ibm.com/software/sysmgmt/products/support/IBM_TSM_Support ed_Devices_for_AIXHPSUNWIN.html Thanks Leigh -----Original Message----- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On Behalf Of Sujay Dinakar R. Sent: 14 November 2006 13:37 To: ADSM-L@VM.MARIST.EDU Subject: [SPAM: 14.000] [ADSM-L] Library not recognised - URGENT Dear All, Recently our IBL 3581 L17 Library is replaced with new one. after connecting the new library Tivoli is not able to recognise the library. Library status is Unknown it says Library intialization failed lb2.0.0.3 we had changed the SCSI ID of the library and tried, the library is defining correctly, where as the define path is giving I/O error. *******Log from the server 11/14/2006 13:07:57 ANR2017I Administrator ADMIN issued command: DEFINE LIBRARY lb4.0.0.3 libtype=scsi 11/14/2006 13:07:57 ANR8400I Library LB4.0.0.3 defined. 11/14/2006 13:07:57 ANR2017I Administrator ADMIN issued command: DEFINE PATH TSMSERVER lb4.0.0.3 srctype=server desttype=library device=lb4.0.0.3 11/14/2006 13:08:17 ANR8840E Unable to open device LB4.0.0.3 with error -1. 11/14/2006 13:08:17 ANR8418E DEFINE PATH: An I/O error occurred while accessing library LB4.0.0.3. 11/14/2006 13:08:17 ANR2017I Administrator ADMIN issued command: ROLLBACK ******** Please any one guide me what should i do?? my entire backup is down??? **** Regards Sujay Dinakar .R