Hi list, I had a problem this morning, where I lost one of the LTO1 drives of our 3584 library. I then opened a call by IBM, and like always, their first advice was to upgrade the Atape driver to latest version (9.6.0.0) and to delete/redefine the drive at AIX (5.3.0) level. I followed their recommendations, to no success, as it was in fact due to some faulty Fiber connection, what I discovered later ... Off course, to perform the Atape driver upgrade, I had to stop TSM server, thus avoiding any eventual tape access ... My problem appeared when I tried to restart the server, under the form of this message in activity log :
11/08/05 12:26:15 ANR8963E Unable to find path to match the serial number defined for drive LTO1DR6 in library LTOLIB1 . 11/08/05 12:26:16 ANR9999D mmsscsi.c(7771): ThreadId<18> Unable to restore library drive state for LTOLIB1. 11/08/05 12:26:16 ANR9999D ThreadId<18> issued message 9999 from: <-0x000000010001bf88 outDiagf <-0x00000001005b87d8 PerformInit <-0x00000001005b89e0 InitThread <-0x00000001 0000e958 StartThread <-0x09000000005412dc _pthread_body 11/08/05 12:26:16 ANR8440E Initialization failed for SCSI library LTOLIB1; will retry in 2 minute(s). I had to remove the path and drive definitions for the faulty drive, to finally get the whole library initialized ! This seems very strange to me, as, AFAIR, I've never seen such a behavior ... We upgraded recently to TSM 5.3.1.4 : is it a new "function" which was introduced at this level ? Anyway, I find it pretty strange that a whole library could not be initialized just because of one missing drive... Anybody having an explanation ? TIA. Cheers. Arnaud ************************************************************************ ****** Panalpina Management Ltd., Basle, Switzerland, CIT Department Viadukstrasse 42, P.O. Box 4002 Basel/CH Phone: +41 (61) 226 11 11, FAX: +41 (61) 226 17 01 Direct: +41 (61) 226 19 78 e-mail: [EMAIL PROTECTED] ************************************************************************ ******