Hi Goran,
Yes, you need to do label libvolume on new tapes. You can use volume
without
sticky label in TSM, but not without "magnetic label" on tape. I
think that
error you got during labeling is not TSM problem, it seems like
drive-tape
comaptibility problem. What is element 261, is it drive? If yes, is
it LTO3
or LTO1 drive? I think you cannot label LTO3 tape in LTO1 drive.
Tom
-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] Behalf
Of goc
Sent: Wednesday, September 07, 2005 10:42 AM
To: ADSM-L@VM.MARIST.EDU
Subject: LTO3 tapes problem !
Importance: High
hi all,
we added D52 frame with 6 LTO3 drives and 220 LTO3 tapes,
in frame 1 there is 226 LTO1 tapes and 12 LTO1 drives
all went fine, except automatic microcode downgrade on
new frame which resulted into configuration failure coz firmware
on frame 1 was old enough (3480) not to recognize D52 frame
during configuratio, so upgrade microcode to latest before starting
frame upgrade ... huh, why was i here ? oh yes ...
since the labels are sticked on new LTO3 cartridges do i need to do
label libvolume ... checkin=scrach or is checkin libvolume enough ?
during LABEL LIBVOLUME i got this errors :
ANR8799I LABEL LIBVOLUME: Operation for library LTO_LIB01 started as
process
8.
ANR8300E I/O error on library LTO_LIB01 (OP=00006C03, CC=404, KEY=05,
ASC=30, ASCQ=00,
SENSE=70.00.05.00.00.00.00.0A.00.00.00.00.3-
0.00.00.C0.00.06.,
Description=Media incompatibility). Refer to Appendix D in the
'Messages'
manual for recommended action.
ANR8875E An illegal move was attempted involving the media in element
1253
of library LTO_LIB01. Its type is incompatible with the
destination element 261.
ANR8942E Could not move volume V00134 from slot-element 1253 to
slot-element
261.
ANR8802E LABEL LIBVOLUME process 8 for library LTO_LIB01 failed.
ANR0985I Process 8 for LABEL LIBVOLUME running in the BACKGROUND
completed
with completion state FAILURE at 10:26:51.
q: why was he trying to move LTO3 cartidge into LTO1 drive ? i know
it can
read it, but what the hell ?
i read before that 6 or 8 VOLSER character maybe can be a problem, am i
right ? (i will search the mailing list i promise)
i tryed to test with move data from one LTO1 volume to newly created
stgp
with new device class but it waits for a volume ... long :-)
thanks for any input
goran
AIX5.2-ML4 p640 TSM 5.3.1.4
24xLTO1 12xLTO3 2x3584+2xD52
4x2108S16 2xDS4100