On Dec 19, 2004, at 3:55 AM, Sandra wrote:
Dear All, I have LTO 3582 attached on SAN, controlled by Win2k TSM Server at 5.2.3. One of the two drives in the library have gone faulty and so many of my operations fail.
Question: 1-How do I tell TSM to use only one tape? (Definitely no DRM untill this is fixed) 2- When the drive is fixed, how do I tell TSM again to start utilizing that tape?
The following is the error: ANR8963E We were not able to find the path to match the Serial number defined for library library name and drive drive name .
the following is explanation that i found in messages document: Explanation: A device has been swapped and we are not able to get the new path. System Action: . User Response: None.
Kindly enlighten me.
Sandra
The Admin Guide section on Managing Drives ... Updating Drives ... Taking Drives Offline explains such management. Use the UPDate DRive or UPDate PATH command to put a drive or path offline while it is being worked on.
Richard Sims