Also, has the MAXSCRATCH limit for the next stgpool been hit?

-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On Behalf Of
Bill Dourado
Sent: Tuesday, August 10, 2004 4:12 PM
To: [EMAIL PROTECTED]
Subject: Re: DISK POOL

.........have you tried  :

                                         q vol stgp=3494pool
access=readwrite stat=filling
                                          to make sure tapes are
available


                                         q stg 3494pool f=d
                                        check for "Maximum Scratch Tapes
Allowed"

Have you got scratch tapes available in your Library ?


Bill








"Hashim, Shukrie BSP-IMI/211" <[EMAIL PROTECTED]>
Sent by: "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]>
10/08/2004 02:15
Please respond to "ADSM: Dist Stor Manager"


        To:     [EMAIL PROTECTED]
        cc:
        Subject:        DISK POOL


Hi there ppl,

I have a problem with my disk pool(DASDPOOL) .. i have 100% util and the
trigger ... is 30% but I dunno why it's not going to the tape
pool(3494POOL) .. and when I check the tape pool (q vol stgp=3494pool)
..
there are still alot of tapes being status FILLING ... hmmm ..

DASDPOOL      DISK          131,000.0   100.0   100.0     30     0
3494POOL

please advice ...

Shukrie


___________________________ Disclaimer Notice __________________________
This message and any attachments are confidential and should only be read by those to 
whom they are addressed. If you are not the intended recipient, please contact us, 
delete the message from your computer and destroy any copies. Any distribution or 
copying without our prior permission is prohibited.

Internet communications are not always secure and therefore Powergen Retail Limited 
does not accept legal responsibility for this message. The recipient is responsible 
for verifying its authenticity before acting on the contents. Any views or opinions 
presented are solely those of the author and do not necessarily represent those of 
Powergen Retail Limited. 

Registered addresses:

Powergen Retail Limited, Westwood Way, Westwood Business Park, Coventry, CV4 8LG.
Registered in England and Wales No: 3407430

Telephone +44 (0) 2476 42 4000
Fax +44 (0) 2476 42 5432

Reply via email to