Dear Ted 10x for the Rapid answer :-) I manage to solve the problem, after I noticed the the scsi id for the drive was not in the correct order e.g 0,0 0,1 0,2 0,3 it was 0,3 0,1 0,0 0,2 Thus the TSM Server could not open the Device.
Best Regards Robert -----Original Message----- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On Behalf Of Ted Byrne Sent: Thursday, March 11, 2004 2:28 PM To: [EMAIL PROTECTED] Subject: Robert, Did the library load the cartridge in the correct drive? Make sure that the element number that you've defined for the drive /dev/mt1 is the right one for the location of the in the library. What you're describing sounds very much like the way TSM acts if there is a mismatch between device name and element number. Drive device/element numbers do not necessarily stay constant when moving to new hardware. Ted At 07:58 AM 3/11/2004 +0200, you wrote: >Hi to all > >After installing Aix version 5.2 (old version 4.3.3.1) and installing my Tsm >version 5.1.8 (before upgrading to 5.2) when I run a : > > dsmserv restore db devclass=dbbclass volumenames=000042 > >I got an error message unable to open media /dev/mt1 error=46 > >This command load the correct cartridge on the tape but after a while I got >this message. > >I try to change the blocksize on my mt1 device to : 1024 , 512 , 0 without >any success the same error. > > >My robot is a Scalar1000 DLT40/80. > > >Any suggestions will be really appreciate …… > >Regards Robert Ouzen >E-mail: [EMAIL PROTECTED]