Hi John, "dsmc q inclexcl" will only show the incude exclude parameters, not mgmt class parameter. You can see if file is bound to the mgmt class using the GUI, in the backup view, right-click the mouse on the file. To see if it is backed up bound to this mgmt class, use the restore view. Remember to stop/start the scheduler after you change the inclexcl or dsm.opt file.
Best regards, Kolbeinn Josepsson - Systems Engineer Tivoli Certified Consultant - IBM TSM V5.1 www.nyherji.is John Naylor <john.naylor@SCOTTISH-SOUT To: [EMAIL PROTECTED] HERN.CO.UK> cc: Sent by: "ADSM: Dist Stor Subject: Inclexcl not picking up Management Class Manager" <[EMAIL PROTECTED]> 07.02.2003 15:54 Please respond to "ADSM: Dist Stor Manager" Hi All, I have an annoying problem Hopefully the Doc will be able to fix me up Seriously, I need to make a particular drive in a WINNT client use large capacity tapes for its backups I have a management class "LARGE" which does this and works for other clients in this domain For this particular client, however we code the option file and we have tried a lot of variations it insists on seeing this line per query inclexcl :- include d:* large as include d:/.../* I know the line is being read because the query incl/excl shows it in a different position if I move it around in the options file. The full options file follows:- PASSWORDACCESS GENERATE TCPSERVERADDRESS IBMBK NODENAME BOXWA009 schedmode prompted DOMAIN c: D: E: L: include d:* large Exclude.File "e:\pagefile.sys" EXCLUDE.DIR "c:\temp" EXCLUDE.DIR "c:\Program Files\Sophos SWEEP for NT" EXCLUDE.DIR "c:\Documents And Settings" EXCLUDE.FILE "c:\WINNT\system32\config\default" EXCLUDE.FILE "c:\WINNT\system32\config\default.log" EXCLUDE.FILE "c:\WINNT\system32\config\sam" EXCLUDE.FILE "c:\WINNT\system32\config\sam.log" EXCLUDE.FILE "c:\WINNT\system32\config\security" EXCLUDE.FILE "c:\WINNT\system32\config\security.log" EXCLUDE.FILE "c:\WINNT\system32\config\software" EXCLUDE.FILE "c:\WINNT\system32\config\software.log" EXCLUDE.FILE "c:\WINNT\system32\config\system" EXCLUDE.FILE "c:\WINNT\system32\config\system.alt" EXCLUDE.FILE "c:\Program Files\Tivoli\TSM\baclient\dsmsched.log" EXCLUDE.FILE "c:\WINNT\system32\dns\dns.log" EXCLUDE.FILE "c:\WINNT\system32\PERFLIB_*.*" Thanks for any input, John ********************************************************************** The information in this E-Mail is confidential and may be legally privileged. It may not represent the views of Scottish and Southern Energy plc. It is intended solely for the addressees. Access to this E-Mail by anyone else is unauthorised. If you are not the intended recipient, any disclosure, copying, distribution or any action taken or omitted to be taken in reliance on it, is prohibited and may be unlawful. Any unauthorised recipient should advise the sender immediately of the error in transmission. Scottish Hydro-Electric, Southern Electric, SWALEC and S+S are trading names of the Scottish and Southern Energy Group. **********************************************************************