Why not just update the library definition?  Remove all the tapes from
Lib-1, insert them in Lib-2;  audit lib on Lib-1 after removing all tapes,
change the Lib def to Lib-2, make the physical connections, dev-class uses
same lib, all is copasetic (zero data movement, since drive type/format is
the same, you're doing the equivalent to Unix "mv" process.)

Don France
Technical Architect -- Tivoli Certified Consultant
Tivoli Storage Manager, WinNT/2K, AIX/Unix, OS/390
San Jose, Ca
(408) 257-3037
mailto:[EMAIL PROTECTED]

Professional Association of Contract Employees
(P.A.C.E. -- www.pacepros.com)



-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED]]On Behalf Of
william derksen
Sent: Wednesday, July 24, 2002 3:43 PM
To: [EMAIL PROTECTED]
Subject: Swappin Silos


We are running a TSM server attached to an iceberg using Gresham's EDT.   I
would like to know the best way to move operations to a newer silo on the
same TSM server.  The tape media for the current silo and the replacement
silo is to be the same format.

It would be nice if clients could be moved over the new silo incrementally
i.e., both libraries operational at the same.

Move data, checkout checkin, export import?

I've searched through the docs on this and have yet to find much help.

Advice and suggestions greatly appreciated.

TIA,

biru




biru_2000 the biru of the new millenium.


---------------------------------
Do You Yahoo!?
Yahoo! Health - Feel better, live better

Reply via email to