I tried this out very briefly and ran into 3 bugs (nohting serious but I decided to wait a while for any other bugs to be flushed out before using this in production) 1. IC32620 If schedule managed by CAD the TSM SCHEDULE service will always be set to start up as MANUAL. The CAD that manages the TSM SCHEDULE will be set to the MANUAL or AUTOMATIC as selected in the wizard.
2 .IC32752 If the wizard specifies to start scheduler managed by CAD Automatically then the wizard should also start the CAD immediately". 3. IC32617 Will address error messages: Event ID - 4099. Scheduler Terminated, service ending. Event ID - 4099. Scheduler exited unexpectedly with a result of 0. We run in SCHEDMODE PROMPTED and NEVER have to restart the TSM Schedule Service to pick up new schedules. Tim Rushforth City of Winnipeg -----Original Message----- From: Thomas Gaines [mailto:[EMAIL PROTECTED]] Sent: Thursday, February 28, 2002 9:46 PM To: [EMAIL PROTECTED] Subject: Managedservices and CAD Hi all, Just wondering what kind of experiences people have had running the MANAGEDSERVICES client option under Win2k. Any particular problems to look out for? My intention is to use CAD to manged the scheduling service. I have not tested as yet but would also like to know that if I am running with SCHEDMODE PROMPTED will the CAD pick up a new schedule when contacted by the TSM server, or will I have to restart the TSM Client Acceptor Service, just as we've had to in the past with the scheduling service under Winnt? Any feedback appreciated Cheers, Tom. Thomas Gaines Technical Specialist WIB Systems Management IBM GSA [EMAIL PROTECTED]