I tried this out very briefly and ran into 3 bugs (nohting serious but I
decided to wait a while for any other bugs to be flushed out before using
this in production)
1. IC32620
If schedule managed by CAD the TSM SCHEDULE service will always be set to
start up as MANUAL. The CAD that manages the TSM SCHEDULE will be set to the
MANUAL or AUTOMATIC as selected in the wizard.

2 .IC32752
If the wizard specifies to start scheduler managed by CAD Automatically then
the wizard should also start the CAD immediately".
3. IC32617
Will address error messages:
Event ID - 4099. Scheduler Terminated, service ending.  Event ID - 4099.
Scheduler exited unexpectedly with a result of 0.

We run in SCHEDMODE PROMPTED and NEVER have to restart the TSM Schedule
Service to pick up new schedules.

Tim Rushforth
City of Winnipeg

-----Original Message-----
From: Thomas Gaines [mailto:[EMAIL PROTECTED]]
Sent: Thursday, February 28, 2002 9:46 PM
To: [EMAIL PROTECTED]
Subject: Managedservices and CAD


Hi all,

Just wondering what kind of experiences people have had running the
MANAGEDSERVICES client option under Win2k. Any particular problems to look
out for? My intention is to use CAD to manged the scheduling service.

I have not tested as yet but would also like to know that if I am running
with SCHEDMODE PROMPTED will the CAD pick up a new schedule when contacted
by the TSM server, or will I have to restart the TSM Client Acceptor
Service, just as we've had to in the past with the scheduling service under
Winnt?

Any feedback appreciated

Cheers,

Tom.

Thomas Gaines
Technical Specialist
WIB Systems Management
IBM GSA
[EMAIL PROTECTED]

Reply via email to