Werner, I have a 4.2 OS390 TSM server and my tso admin client is 3.1.0.7 and works fine. regards, John
Werner Nussbaumer <[EMAIL PROTECTED]> on 12/18/2001 11:27:37 AM Please respond to "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]> To: [EMAIL PROTECTED] cc: (bcc: John Naylor/HAV/SSE) Subject: Re: dsmadmc OS/390 TSO Abends After UserID/Password I saw that the administrative client DSMADMC is version 3.1 and the server is 4.1. Maybe this is the problem. Regards Werner Nussbaumer -----Original Message----- From: Nussbaumer, Werner Sent: Montag, 17. Dezember 2001 15:42 To: 'ADSM User List' Subject: dsmadmc OS/390 TSO Abends After UserID/Password Hi all On our OS/390 TSO system we tried to start dsmadmc -consolemode dsmadmc asks for the userID and password. After the userID was entered dsmadmc abends with code 000C1000: ********************************************************************* ADSTAR Distributed Storage Manager Command Line Administrative Interface - Version 3, Release 1, Level 0.7 (C) Copyright IBM Corporation, 1990, 1999, All Rights Reserved. Enter your user id: t096058 Enter your password: T096058 abending: MVS Abend code 000C1000 generated at location 80000004 CPU 0 General Registers at Entry to Abend: R00 = 0000023C 22094F88 223B27B8 2220569A R04 = 00073058 22094EE4 00000000 223B21D8 R08 = 00000000 00000008 22094268 A2053BBE R12 = 00059000 22094EF0 A22056E4 00000000 CPU 0 Access Registers at Entry to Abend: A00 = 7F91E010 00000000 00000000 00000000 A04 = 00000000 00000000 00000000 00000000 A08 = 00000000 00000000 00000000 00000000 A12 = 00000000 00000000 016FFC18 81369972 Calling Trace for Current Task: 13 *-* "DSMADMC -CONSOLEMODE" +++ RC(-194) +++ ********************************************************************* Does anyone know how to solve this problem? Thanks a lot, Regards Werner Nussbaumer ********************************************************************** The information in this E-Mail is confidential and may be legally privileged. It may not represent the views of Scottish and Southern Energy plc. It is intended solely for the addressees. Access to this E-Mail by anyone else is unauthorised. If you are not the intended recipient, any disclosure, copying, distribution or any action taken or omitted to be taken in reliance on it, is prohibited and may be unlawful. Any unauthorised recipient should advise the sender immediately of the error in transmission. Scottish Hydro-Electric, Southern Electric, SWALEC and S+S are trading names of the Scottish and Southern Energy Group. **********************************************************************