Try putting the tapes in the slots in the library rather than in the bulk
port. Change your command to search=y and see if that works. Maybe only
put some of the tapes in and leave the rest for future bulk testing. I've
seen this before but in my brain addled state I can't remember what the
problem was. I'll keep pondering and perhaps it will come to me.
Kelly J. Lipp
Storage Solutions Specialists, Inc.
PO Box 51313
Colorado Springs CO 80949-1313
(719) 531-5926
Fax: (240) 539-7175
Email: [EMAIL PROTECTED] or [EMAIL PROTECTED]
www.storsol.com
www.storserver.com
-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED]]On Behalf Of
Mahesh Tailor
Sent: Thursday, June 14, 2001 10:07 AM
To: [EMAIL PROTECTED]
Subject: Re: TSM and 3583 LTO Library
Here's my q drive output:
Library Name Drive Name Device Type Device ON
LINE
------------ ------------ ----------- ----------------
-------------------
3575LIB RMT0 3570 /dev/rmt0
Yes
3575LIB RMT1 3570 /dev/rmt1
Yes
3575LIB RMT2 3570 /dev/rmt2
Yes
3575LIB RMT3 3570 /dev/rmt3
Yes
3575LIB RMT4 3570 /dev/rmt4
Yes
3575LIB RMT5 3570 /dev/rmt5
Yes
3583LIB RMT6 LTO /dev/rmt6
Yes
3583LIB RMT7 LTO /dev/rmt7
Yes
3583LIB RMT8 LTO /dev/rmt8
Yes
I had not done an audit library, I just executed that command. Here's
the audit library log entries:
06/14/01 12:04:09 ANR8461I AUDIT LIBRARY process for library
3583LIB
completed successfully.
06/14/01 12:04:09 ANR0985I Process 84 for AUDIT LIBRARY running in
the
BACKGROUND completed with completion state
SUCCESS at
12:04:09.
And, then tried the label and checkin again but it failed with the same
set of errors.
Mahesh
>>> [EMAIL PROTECTED] 06/14/01 11:50AM >>>
Haven't worked with this library but:
Do a q drive and make sure drives are there and online.
Did you do an audit library after setting up the new library?
David Longo
>>> [EMAIL PROTECTED] 06/14/01 11:45AM >>>
Hello, all!
I have just SCSI attached an IBM 3583 LTO library to my TSM server.
Installed the latest verstion of Atape and AIX recognizes the library as
follows:
rmt6 Available 10-68-00-0,0 IBM 3580 Ultrium Tape Drive
rmt7 Available 10-68-00-1,0 IBM 3580 Ultrium Tape Drive
rmt8 Available 10-68-00-2,0 IBM 3580 Ultrium Tape Drive
smc1 Available 10-68-00-6,0 IBM 3583 Library Medium Changer
Here's what I have:
- Atape 6.0.4.0
- AIX 4.3.2.0
- TSM 3.7.4.0.
- 3583 firmware 2.05.0003 and sled version 2.01.0001
Once the OS recognized the library, I executed the following commands to
define the library in TSM.
DEFINE LIBRARY 3583lib libtype=scsi device=/dev/smc1
DEFINE DRIVE 3583lib RMT6 device=/dev/rmt6 element=256
DEFINE DRIVE 3583lib RMT7 device=/dev/rmt7 element=257
DEFINE DRIVE 3583lib RMT8 device=/dev/rmt8 element=258
DEFINE DEVCLASS 3580 devtype=lto format=ultriumc libra=3583lib
estcapa=100G
DEFINE STGPOOL ONSITE 3580 DESCRIPTION="3583 LTO Library"
ACCESS=READWRITE MAXSIZE=NOLIMIT HIGHMIG=90
LOWMIG=70
COLLOCATE=NO RECLAIM=100 MAXSCRATCH=999
REUSEDELAY=0
MIGDELAY=0 MIGCONTINUE=YES
The commands all ran successfully. I then tried to label and checkin a
tape. I issued the following command:
LABEL libv 3583lib search=b labels=b checkin=
I replied the REQUEST and then after about 30 seconds the command
completes without doing anything with the tape. I get the following
entries in the actlog.
06/13/01 14:01:07 ANR8373I 003: Fill the bulk entry/exit port of
library
3583LIB with all LTO volumes to be processed
within 60
minute(s); issue 'REPLY' along with the
request
ID when
ready.
06/13/01 14:01:11 ANR2017I Administrator ADMIN issued command:
REP
003
06/13/01 14:01:11 ANR8499I Command accepted.
06/13/01 14:01:21 ANR8300E I/O error on library 3583LIB
(OP=00006C03,
CC=207, KEY=05, ASC=83, ASCQ=03,
SENSE=70.00.05.00.00.00.00.0A.00.00.00.00.83.03.46.00.00-
.00., Description=Device is not in a state
capable of
performing request). Refer to Appendix B in
the
'Messages' manual for recommended action.
06/13/01 14:01:21 ANR9999D mmsscsi.c(11395): Could not move
volume
from slot
16 to slot 257.
06/13/01 14:01:21 ANR8841I Remove volume from slot 16 of library
3583LIB at
your convenience.
06/13/01 14:01:22 ANR8802E LABEL LIBVOLUME process 47 for library
failed.
06/13/01 14:01:22 ANR0985I Process 47 for LABEL LIBVOLUME running
in the
BACKGROUND completed with completion state
FAILURE at
14:01:22.
Yes, the library is online when I do this. :-)
Has anyone seen this? What can I do to fix the problem? Have I missed
a
step?
TIA
Mahesh Tailor
WAN Administrator
Carilion Health System
Voice: 540-224-3929
Fax: 540-224-3954
"MMS <health-first.org>" made the following
annotations on 06/14/01 11:53:14
----------------------------------------------------------------------------
--
This message is for the named person's use only. It may contain
confidential, proprietary, or legally privileged information. No
confidentiality or privilege is waived or lost by any mistransmission. If
you receive this message in error, please immediately delete it and all
copies of it from your system, destroy any hard copies of it, and notify
the sender. You must not, directly or indirectly, use, disclose,
distribute, print, or copy any part of this message if you are not the
intended recipient. Health First reserves the right to monitor all e-mail
communications through its networks. Any views or opinions expressed in
this message are solely those of the individual sender, except (1) where
the message states such views or opinions are on behalf of a particular
entity; and (2) the sender is authorized by the entity to give such views
or opinions.
============================================================================
==