I to have several volumes with this same problem.  After talking to TSM
support they recommend doing a dsmserv auditdb archstorage fix=yes.  However
this is now APAR IC28965.  The fix is due out in May.  You may want to wait,
as the auditdb can take days.

Ray Baughman
Engineering Systems Administrator
TSM Administrator
National Machinery Co.
Phone:   419-443-2257
Fax:     419-443-2376
Email:   [EMAIL PROTECTED]

> -----Original Message-----
> From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED]]On Behalf Of
> Alan Davenport
> Sent: Monday, March 19, 2001 12:43 PM
> To: [EMAIL PROTECTED]
> Subject: Re: no "delete volume" because of segment references
>
>
> Have you tried an audit volume"
>
> AUDIT VOLUME xxxxxx FIX=YES
>
> Perhaps this will clear it up for you.
>
> Alan Davenport
> Selective Insurance
> [EMAIL PROTECTED]
>
> [EMAIL PROTECTED] wrote:
> >
> > From: [EMAIL PROTECTED]
> > To: [EMAIL PROTECTED]
> > Date: Mon, 19 Mar 2001 18:01:56 +0100
> > Subject: no "delete volume" because of segment references
> >
> > Hi *SM'ers !
> >
> > In order to remove a storage pool that is no longer in use, I
> tried to delete all volumes belonging this storage pool, what
> worked perfectly except for one volume that was already empty,
> where I got this message :
> > 03/19/01 17:24:08 ANR2017I Administrator xxxx issued command:
> DELETE VOLUME 0BA40C discard=yes
> > 03/19/01 17:24:09 ANR1423W Scratch volume 0BA40C is empty but
> will not be deleted - volume access mode is "offsite".
> > So far I agree, but what annoyes me is the following : I tried
> then this command :
> > 03/19/01 17:24:41 ANR2017I Administrator xxxx issued command:
> UPDATE VOLUME 0BA40C acces=readwrite
> > that was supposed to induce an automatic deletion of the
> volume, but I obtained the following result :
> > 03/19/01 17:24:46 ANR9999D asvol.c(2847): Volume 0BA40C cannot
> be deleted to SCRATCH - it still has SEGMENT references.
> > 03/19/01 17:24:46 ANR9999D asvol.c(1726): Unknown result code
> (267) while deleting a volume.
> > Did anybody ever face this kind of problem, and what was the
> solution for it ?
> > Thanks in advance for any help !
> > Arnaud
> >
> > =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
> > | Arnaud Brion, Panalpina Management Ltd., IT Group     |
> > | Viaduktstrasse 42, P.O. Box, 4002 Basel - Switzerland |
> > | Phone: +41 61 226 19 78    /    Fax: +41 61 226 17 01 |
> > =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
>

Reply via email to