If the tapes are prelabeled, I would just check them in....
        I have had new, unlabeled tapes that have had issues writing the
tape label. I have those tapes replaced.
        (we peel off the bar coded label and lay it down on another blank
tape and label libv that one....we also have double stick tape (special) in
case
        the stickum isn't too sticky).
        If you are having lots of problems with the whole box of 3590 tapes,
then this could point to a tape problem....
        One idea of trouble shooting....take drive 5 offline...does the
problem 'travel'
        Also...try labeling the specific tape...again...with tape drive 5
offline....same problem? If so, replace the tape.
        FYI Thanks Tim
        *One more thing....yes, I've had problems with NEW tapes...





        Debbie Denham <[EMAIL PROTECTED]>
        10/27/2000 11:47 AM
        Please respond to "ADSM: Dist Stor Manager"
<[EMAIL PROTECTED]>@SMTP@Exchange
        To:     [EMAIL PROTECTED]@SMTP@Exchange
        cc:

        Subject:        NEW 3590 CARTRIDGES

        I have a question regarding new out of the box 3590 prelabel tape
cartridges. Below are the logs I am receiving.
        Are there any others that have had similar problems labeling new
volumes. I have had similar problems on different drives and cartridges. Is
the problem the cartridge or the drive? I would appreciate any help.

        Thanks in advance,
        Debbie Denham

        10/27/2000 11:59:58 ANR2017I Administrator ADMIN issued command:
LABEL libv 3494a search=yes checkin=scratch devt=3590

        10/27/2000 12:09:25 ANR8302E I/O error on drive DRIVE5 (/dev/rmt5)
(OP=WRITE, CC=0, KEY=03, ASC=0C, ASCQ=00,
SENSE=F0.00.03.00.00.00.50.58.00.00.00.00.0C.00.FE.02.31.18.50.55.00.03.01.3
1.48.06.43.49.42.14.0A.00.10.35.42.12.01.33.6B.0F.04.33.54.10.07.00.00.00.00
.00.00.00.00.00.00.00.00.10.FF.FF.FF.FF.00.00, Description=An undetermined
error has occurred).  Refer to Appendix B in the 'Messages' manual for
recommended action.
        10/27/2000 12:09:25 ANR8806E Could not write volume label 002512 on
the tape in library 3494A.


        LABEL:          TAPE_ERR1
        IDENTIFIER:     4865FA9B

        Date/Time:       Fri Oct 27 12:09:25
        Sequence Number: 196073
        Machine Id:      006194834C00
        Node Id:         shsilo1
        Class:           H
        Type:            PERM
        Resource Name:   rmt5
        Resource Class:  tape
        Resource Type:   3590
        Location:        50-58-00-5,0
        VPD:
                Manufacturer................IBM
                Machine Type and Model......03590E1A
                Serial Number...............000000021632
                Device Specific.(FW)........D22E
                Loadable Microcode Level....A0B00E26

        Description
        TAPE OPERATION ERROR

        Probable Causes
        TAPE

        User Causes
        MEDIA DEFECTIVE
        DIRTY READ/WRITE HEAD

                Recommended Actions
                FOR REMOVABLE MEDIA, CHANGE MEDIA AND RETRY
                PERFORM PROBLEM DETERMINATION PROCEDURES

        Detail Data
        SENSE DATA
        0605 0000 0A00 0000 5000 0000 0000 0000 0000 0000 F000 0300 0000
5058 0000 0000
        0C00 FE02 3118 5055 0003 0131 4806 4349 4214 0A00 1035 4212 0133
6B0F 0433 5410
        0700 0000 0000 0000 0000 0000 0010 FFFF FFFF 0000 0100 0000 3100
2000 3232 4520
        2020 2000 C000 4A30 3032 3531 3200 0000 0000 0000 0000 0000 0000
0000 0000 0000
        0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000

---------------------------------------------------------------------------
        LABEL:          DEV_DUMP_RETRIEVED
        IDENTIFIER:     DE9A52D1
        LABEL:          DEV_DUMP_RETRIEVED
        IDENTIFIER:     DE9A52D1

        Date/Time:       Fri Oct 27 12:09:25
        Sequence Number: 196072
        Machine Id:      006194834C00
        Node Id:         shsilo1
        Class:           S
        Type:            INFO
        Resource Name:   rmt5

        Description
        DEVICE DUMP RETRIEVED

        Probable Causes
        TAPE DRIVE

        Failure Causes
        TAPE DRIVE

                Recommended Actions
                CONTACT APPROPRIATE SERVICE REPRESENTATIVE

        Detail Data
        Detail Data
        ADDITIONAL INFORMATION
        Device dump saved as /var/adm/ras/Atape.rmt5.dump_h3

Reply via email to